Add to Cart
No. | Item
| General Parameter
| Remark
|
1 | Rated Capacity
| 20.0Ah | Standard discharge(0.2 C5)after standard charge(0.2 C5)
|
2 | Minimal Rated Capacity
| 19.5Ah | |
3 | Nominal Voltage
| 12.8V | |
4 | Cycle Life
| Higher than 60% of the Initial Capacity of the Cells 60%) | Charge: CC@0.2C to 14.6V, then CV till current to 0.05C Rest: 30min. Discharge: 0.2C to 10.0V Temperature:20±5℃ Carry out 2000cycles
|
5 | Discharge cut-off voltage
| 9.2V | 10.0V( recommended)
|
6 | Charging cut-off voltage
| 14.8V | 14.6V (recommended)
|
7 | Cell and assembly method
| IFR18650-3.3AH | 4S8P |
8 | Housing material
| PVC |
No.
| Item
| General Parameter
| Remark
|
9 | Standard charge
| 0.2C constant current(CC) charge to 14.6V,then constant voltage (CV)14.6V charge till charge current decline to ≤0.05C
| Charge time : Approx 7h
|
10 | Standard discharge
| Constant current 0.2C Cut-off voltage 10.0V
| |
11 | Maximum Charge Current
| 5A | |
12 | Continuous Discharge Current
| 10A | |
13 | Operation Temperature Range
| Charge: 0~45℃ | 60±25%R.H.
|
Discharge: -10~60℃ | |||
14 | Storage Temperature Range
| Less than 1 year : 0~25℃
| 60±25%R.H. at the shipment state
|
Less than 3 months:-5~35℃
| |||
15 | Weight
| Approx 2.20Kg | |
16 | Max. Dimension
| thickness:30mm |
|
Width: 159mm | |||
Length: 272mm |
each pack protect by sponge bag and each bag in each box,then 5 set in one export carton
25-35 days after you confirm the order
we ship out the batter pack samples by UPS TNT DHL etc
And ship out the mass product by air and ocean with your require
1 Test should be conducted with new batteries within one week after shipment from our factory and the batteries shall not be cycled more than five times before the test. Unless otherwise specified, test and measurement shall be done under temperature of 20±5℃ and relative humidity of 45~85%. If it is judged that the test results are not affected by such conditions, the tests may be conducted at temperature 15~30℃ and humidity 25~85%RH.
2 Dimension Measuring Instrument
The dimension measurement shall be implemented by instruments with equal or more precision scale of 0.01mm.
Standard class specified in the national standard or more sensitive class having inner impedance more than 10kΩ/V
Standard class specified in the national standard or more sensitive class. Total external resistance including ammeter and wire is less than 0.01Ω.
3 Impedance Meter
Impedance shall be measured by a sinusoidal alternating current method (1kHz LCR meter).
4 Standard Charge/Discharge
Standard Charge : 0.2C
Charging shall consist of charging at a 0.2C constant current rate until the battery reaches 14.6V. The battery shall then be charged at constant voltage of 14.6V volts while tapering the charge current. Charging shall be terminated when the charging current has tapered to 0.05 C5A. Charge time: Approx 7.0h, The battery shall demonstrate no permanent degradation when charged between 0 ºC and 45 ºC.
5 If no otherwise specified, the rest time between charging and discharging is 30min.
6 Appearance
There shall be no such defect as crack, rust, leakage, which may adversely affect commercial value of battery.
Our Advantage
12V 100ah solar power storage battery