Add to Cart
12V250AH Lithium Lifepo4 Battery, Deep Cycle Batteries Built-In 200A BMS
About this item:
Battery specifications:
No. | Items | Specifications |
Remark
| |
1 |
Capacity for assembled cell discharging by 0.2C
| ≥201.6AH |
Standard discharging method
| |
2 | Battery Voltage |
12.8-13.2V
|
Delivery voltage, Within 10 days from Factory
| |
3
|
Standard charge condition
|
Charge with 0.2C constant current and 14.6Vconstant voltage, charge to 14.6V continue charging till current declineto ≤0.01C
| Charge voltage: 14.6V±0.02V Charge current:0.2C | |
4 |
Maximum charge current
|
|
150A
|
For continuous charging mod
|
5 |
Maximum discharge current
|
| 150A |
For continuous discharge mod
|
6 |
Standard discharging method
|
0.2C constant current discharge to 8V,
| ||
7 |
Internal Impedance
|
Assemblage Impedance
|
Measure two sides of the drawing line after assembling. .
| |
8 | | 23Kg |
Safty performance:
No. | Items |
Test Method and Condition
|
Criteria
|
1 | Thermal exposure test
|
Each fully charged cell, stabilized at room temperature, is placed in a circulating air-convection oven. The oven temperature is raised at a rate of 5 °C/min ± 2 °C/min to a temperature of 130 °C ± 2 °C. The cell remains at this temperature for 10 min before the test is discontinued.
| No fire, No explosion
|
2 | Low pressure
|
Each fully charged cell is placed in a vacuum chamber, in an ambient temperature of 20~25℃. Once the chamber has been sealed, its internal pressure is gradually reduced to a pressure equal to or less than 11.6 kPa (this simulates an altitude of 15240 m) held at that value for 6 h.
| No leakage, No fire, No explosion
|
3. | Short test
|
The fully charged battery is to be short-circuited by connecting the positive and negative terminals of the battery with resistance load not exceed 100mΩ. Tests are to be conducted at room temperature 20~25℃.
| No fire, No explosion The Temperature of the Battery surface not exceeded than 150℃
|
4 |
Over Discharg
|
(After standard charge. Cells are discharged at constant Current of 0.2C to 2.0V, and the positive and negative terminal is connected by a 30Ω wire for 24 hours. Cell Condition: Fresh, Fully charged cell.)
| No fire, No explosion |
5 | Over charge test
|
After standard charge, continue to charge with a constant voltage 4.8V per a cell, holding 8h.
| No leakage, No fire, No explosion
|
6 | Soak Test
|
Put the batteries into clean water, be soaked for 24 hours.
| No break, No fire
|
Caution:
Risk of Fire , Explosion or Burns
DO NOT Short circuit
DO NOT Reverse connections from charger to battery
DO NOT Disassemble
DO NOT Throw into fire or incinerate
DO NOT Heat above 70C